Introduction
RF-NET Repeater 13
Checking the range
The optional RF-TRACE-MASTER allows you to check the quality
of the radio frequency (RF) link between the OMEGA server and
your locking devices.
The RF-TRACE-MASTER triggers the following signals of your
locking devices:
Green LED of your locking cylinder, IES or wall terminal
flashes twice: very strong RF link.
Green LED of your locking cylinder, IES or wall terminal
flashes once: adequate RF link.
Red LED of your locking cylinder, IES or wall terminal
flashes: RF link is not OK and must be checked.
Red and green LEDs flash alternately or simultaneously:
weak RF link.
To verify the quality of the RF link to your locking devices,
proceed as follows:
Hold the RF-TRACE-MASTER in front of your locking device.
The verification is performed immediately.
During the verification, the Access Point emits the
same signals as the locking device.